Skip to content

Quick start

This walk-through builds a small loop on your own laptop: a simulator produces values, an IEC 104 server exposes them and an IEC 104 client reads them back. No hardware or other software is needed.

  1. Download the latest Protocol Bridge Desktop zip from the download section of the website.
  2. Unzip it to a folder of your choice and start ProtocolBridge.Desktop.exe.

Requirements: Windows 10 or 11 (64-bit) with the Microsoft Edge WebView2 runtime, which is preinstalled on current Windows.

  1. Click New endpoint on the toolbar.
  2. Enter a Name, e.g. Simulator.
  3. Choose the protocol Simulator and the role Client.
  4. Keep the defaults (12 points, updated every 1000 ms) and click Save.

The endpoint appears under Endpoints in the explorer on the left. Open it to see its points change.

  1. Click New endpoint again.
  2. Name it IEC 104 server, choose IEC 60870-5-104 and the role Server.
  3. Keep Listen address 0.0.0.0, Port 2404 and Common address (ASDU) 1.
  4. Click Save.

Mappings are an editable table: you add and change rows in place, then review and apply all the changes at once.

  1. Under Data flow in the explorer, open Mappings and click Add row. A new row appears, marked new.
  2. Fill in its cells (click a cell, choose or type the value, press Enter):
    • Source endpoint: Simulator, Source address: * (every point of the source);
    • Target endpoint: IEC 104 server. Leave Target address empty: every point keeps its address on the server.
  3. Tick Forward commands in the same row, so commands sent to the server reach the simulator.
  4. Click Review and apply on the toolbar, check the line it lists and click Apply 1 change.

Every simulator point is now published by the IEC 104 server under the same address: open IEC 104 server in the explorer to see the values on its Points tab. (The mapping’s Last value column shows a value for a mapping of a single point; with * it stays empty.)

  1. Click New endpoint, name it IEC 104 client, and choose protocol IEC 60870-5-104 and role Client.
  2. Set Host 127.0.0.1 and Port 2404; keep General interrogation on connect on.
  3. Click Save and open the endpoint from the explorer.

The values arrive on the Points tab with their quality and time stamp. Send a command to one of the points with the command link in its row (see Live data and commands): it travels through the server and the mapping back to the simulator, and the client shows the confirmation.